Product Central

 
 
     NT2C:  Vital Signs Monitors
  • Bright, Easy-to-Read Large LED Display
  • Durable, Compact and Lightweight
  • Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
  • Accurate, Reliable Readings During Low Perfusion and Montion
  • Audible/Visual Three Level Alarms with Alarm Volume Control
  • 72-hour Data Memory Allowing On-screen Data Replay
  • Suitable for Adult, Pediatric and Neonate
  • Optional Internal Thermal Recorder
  • Able to Connect to Nurse Call Network

       Product Features :
  • SpO2 Accuracy
    No Motion:
    Adults, Pediatrics: 70~100% ¡À2%
                                  0~69% unspecified
    Neonates:             70~100% ¡À3%
                                  0~69% unspecified
    With Motion:
    Adults, Pediatrics: 70~100% ¡À3%
                                  0~69% unspecified
    Neonates:             70~100% ¡À4%
                                  0~69% unspecified
    Low Perfusion:
    Adults, Pediatrics: 70~100% ¡À3%
                                  0~69% unspecified
    Neonates:             70~100% ¡À4%
                                  0~69% unspecified

  • Pulse Rate Accuracy
    No Motion:
    Adults, Pediatrics, Neonates: ¡À3%
    With Motion:
    Adults, Pediatrics, Neonates: ¡À5%
    Low Perfusion:
    Adults, Pediatrics, Neonates: ¡À5%

  • Non-Invasive Blood Pressure
    Measurement type:
    Adult, Pediatric, Neonatal
    Measurement range:
    Adult:
    Systolic    40bpm~270mmHg
    Diastolic  20bpm~200mmHg
    Mean       30bpm~220mmHg
    Pediatric:
    Systolic    40bpm~180mmHg
    Diastolic  15bpm~160mmHg
    Mean       20bpm~170mmHg
    Neonatal:
    Systolic    30bpm~140mmHg
    Diastolic  15bpm~100mmHg
    Mean       20bpm~115mmHg
    Accuracy: ¡À3mmHg or 2%(choice max)
    Resolution: 1mmHg
    Protection: over pressure
  • Performance Measurement Range
    SpO2:0¡«100%
    Pulse Rate: 30bpm~250bpm

  • Alarm
    Audible/Visual Alarms
    Adjustable Alarm Limits

  • Temperature
    Measurement range: 25¡«45¡æ
    Accuracy: ¡À0.2¡æ

  • Output
    RS-232 Serial Port for Digital Output
    Nurse Call Function

  • Electrical Instrument
    Power Requirements:
    100~240VAC, 50/60Hz, 20VA
    Fuse Rating: 1.0A

  • Battery
    Internal Battery: 12V ¡¡
    Battery Capacity: ¡Ý 24 hours

  • Environment
    Opreation Temperature: 5¡«40¡æ
                                           41~104¨H
    Humidity: 10~95%
    Transport/Storage Temperature:
    -20¡«+70¡æ (-4¨H~158¨H)
    Humidity: 10~95%

  • Physical Characteristics
    Dimensions:
    264mm(W) x 95mm(H) x 172mm(D)
    [10.39in(W) x 3.74in(H) x 6.77in(D)
    Net Weight: 2.25kg/5ib

  • Compliance
    EN60601-1/ GB9706.1
    EN60601-1-2, EN60601-2-49

  • One adult finger SpO2 sensor is included with each unit
NEWTECH,  INC.     Copyright  2006