Shenzhen Newtech,Inc.
Address: Unit C, 1st Chuangye Building, 6th Industrial Rd., Nanshan District,
Shenzhen, Guangdong 518067, P.R.China
E-mail: intl-sales@sznewtech.com
Tel: +86-755-2652 5848
Fax: +86-755-2652 0737
Website: www.sznewtech.com
NT1G HandheldCapnography/Pulse Oximeters
    Download 1:Product material one
    Product Name:NT1G HandheldCapnography/Pulse Oximeters

    Product Features
    • Durable, Compact, and LightWeight

    • Capnograph with Trends

    • SpO2 with Waveforms

    • Data Storage for up to 100 Patients; 72-Hour Data Storage for Each Patient

    • Wireless Data Transmission

    • Suitable for Adult, Pediatric and Neonate

     

    Product Specification

     

     

     

    Measurement Range

    Electrical

    SpO2: 0%~100%

    SpMet:0-99.9%

    SpCO:0-99%

    SPHb:0-25g/dl

    SpOC:0-3535ml of O2dl of blood

    AC Power Requirements: 100~240 VAC, 50-60 Hz,

    Power Consumption: 5V 2A

     

    Battery

    Type: Li Battery

    Pulse Rate:25bpm-240bpm

    Perfusion Index: 0.02-20%

    PVI:0-100%

    Capacity(Battery life): Up to 4hours

    Charging time: 8 hours

     

     

    Environmental

    Oxygen Saturation Accuracy SpO2

    Operating Temperature: 5 to 40 (41°F to 104°F)

    Saturation: 60-80%

    No Motion

    Accuracy (Adults/Infants/Pediatrics): ± 3%

    Saturation:70-100%

    No Motion

    Accuracy (Adults/Infants/Pediatrics): ± 2%

    Accuracy (Neonates): ± 3%

    Motion

    Accuracy Adults/Infants/Pediatrics/Neonates): ± 3%

    Low Perfusion

    Accuracy (Adults/Infants/Pediatrics/Neonates): ± 3%

     

    Operating Humidity: 5% to 95%, No Condensing

    Storage Temperature: -40 to 70 (-40°F to 158°F)

    Operating altitude: 500 mbar to 1060 mbar pressure

                    -1000 ft to 18,000 ft (-304m to 5486m)

     

     

    Alarms

    Three Levels of Visual, Audio alarms 

     

    Data Storage and Transmission

    SD Card 8/16 GB Selectable & Wi-Fi

     

     

    Pulse Rate Accuracy

    Measurement Range: 25-240bpm

    No Motion

    EtCO2 and FiCO2

    Measurement Range: 0-25%

    Accuracy: 0-15% ±(0.2 Vol% +2% of reading)

    ±(0.3Vol% +4% of reading) incl. interfering gases

    Adults/Infants/Pediatrics/Neonates: ±3 bpm

    Motion

    Adults/Infants/Pediatrics/Neonates: ±5 bpm

    Low Perfusion

    Adults/Infants/Pediatrics/Neonates: ±3 bpm

    Respiration Rate

    Measurement Range: 0-150 breaths/min

    Accuracy: ±1 bpm

     

    Physical Characteristics

    Carboxyhemoglobin Saturation Accuracy (%SpCO)

    Dimensions: 156mm(W) x 84mm(H) x 27.7mm(D)

    Adults/Infants/Pediatrics: 1-40%± 3%

    Maximum Weight: 300g

     

     

    Methemoglobin Saturation Accuracy (%SpMet)

    Pleth Variability Index(PVI), Perfusion Index (PI)

    Adults/Infants/Pediatrics/Neonates:1-15%± 1%

     

    Total Hemoglobin Accuracy (SpHb g/dL)

    Oxygen Content(SpOC)

    Measurement Range(SpOC): 0-35ml of O2/dl of blood

    Measurement Range (PVI): 0-100%

    Adults/Pediatrics: 8-17g/dL± 1 g/dL

    Measurement Range(PI):0.02-20%

     

    Resolution

    Oxyhemoglobin Saturation (%SpO2):1%

    Carboxyhemoglobin Saturation (%SpCO), digital display: 1%

    Methemoglobin Saturation (%SpMet), digital display: 0.1%

    Total Hemoglobin(SpHb g/dL): 0.1g/dL

     

     

    Pulse Rate(bpm): 1bpm