Shenzhen Newtech,Inc.
Address: Unit C, 1st Chuangye Building, 6th Industrial Rd., Nanshan District,
Shenzhen, Guangdong 518067, P.R.China
E-mail: intl-sales@sznewtech.com
Tel: +86-755-2652 5848
Fax: +86-755-2652 0737
Website: www.sznewtech.com
NT2C Vital Signs Monitors
    Download 1:Product material one
    Product Name:NT2C Vital Signs Monitors

    Product Feature
    -----------------------------------------------------------
    Bright, Easy-to-Read Large LED Display
    Durable, Compact and Lightweight 
    Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
    Audible/Visual Three Level Alarms with Alarm Volume Control
    72-hour Data Memory Allowing On-screen Viewing of SpO2 and Pulse Rate Trends
    Suitable for Adult, Pediatric and Neonate
    -----------------------------------------------------------
    Product Specification 
    Performance Measurement Range: Electrical Instrument:
    SpO2: 0%~100% Power Requirements: 100~240VAC, 50/60Hz, 40VA
    Pulse Rate: 30bpm~250bpm Fuse Rating:                 1.0A
    SpO2 Accuracy: Battery:
    Adults, Pediatrics: 70% ~ 100%  ±2% Internal Battery:   12V
                                0%-69% unspecified Battery Capacity:  24 hours
    Neonates:             70% ~ 100%   ±3%
                                0%-69% unspecified Environment:
    Pulse Rate Accuracy: Operating:
    Adults, Pediatrics, Neonates: ±3% Temperature: 5OC~40OC (41OF ~104OF)
    Humidity:         10%~95%   
    Non-Invasive Blood Pressure: Transport/Storage:
    Measurement   type:  Adult, Pediatric, Neonatal Temperature: -20OC~70OC (-4OF ~158OF)
    Measurement range:  Humidity:       10%~95%
    Adult:         Systolic   40 ~  270mmHg
                      Diastolic  20 ~  200mmHg Physical Characteristics:
                      Mean          30 ~  220mmHg Dimensions:    264mm(W) x 95mm(H) x 172mm(D)
    Pediatric:    Systolic    40 ~  180mmHg                      10.39in(W) x 3.74in(H) x 6.77in(D)
                      Diastolic      15 ~  160mmHg Net Weight:    2.25kg/5 Ib
                      Mean       20 ~  170mmHg
    Neonatal:    Systolic    30 ~  140mmHg Compliance:
                     Diastolic   15 ~  100mmHg 1. SpO2: ISO 9919: 2005(E)
                     Mean        20 ~  115mmHg 2. Safety Standards:
    Accuracy:  Meets ANSI/AAMI SP10-1992     EN 60601-1: 1990+A1: 1993+A2: 1995+A13: 1996
    Resolution: 1mmHg 3. Alarm: IEC60601-1-8: 2005
    Protection:  over pressure 4. EMC: EN 60601-1-2: 2007, Group 1 Class A
    5. Environment : WEEE (2002/96/EC)
    Alarm
    Audible/Visual Alarms  Output:
    Adjustable Alarm Limits RS-232 Serial Port for Digital Output 
    Nurse Call Function
    Temperature:
    Measurement range: 25 ~ 45
    Accuracy:               ± 0.2