Product Feature
---------------------------------------------------------
◆10.4" High Resolution Color TFT LCD
◆1-8 Channel Waveform Display
◆7 Leads ECG Waveform Display; ST Segment Analysis
◆Defibrillation and ESU Protection
◆Venous Punch
◆Suitable for Adult, Pediatric and Neonate
◆Standard Configuaration: ECG, NIBP, RESP, TEMP, SpO2
◆Options: Thermal Recorder, CO2, IBP, Central Monitoring Systems
----------------------------------------------------------
Product Specification
◆ECG
◆Respiration
ECG cable: 5 Leads ECG Cable
Measurement range: 0 ~ 120 bpm
Lead selection:Ⅰ,Ⅱ, Ⅲ/ aVR, aVL, aVF/ V
Accuracy: ±1 bpm or ±5 % (take the greater one)
Gain (mm/mV): 1/4, 1/2,1, 2, 4, Manual/Automatic
Sweep speed (mm/sec): 6.25, 12.5, 25, 50
◆Options
Heart rate range: 30~300bpm
EtCO2
Heart rate accuracy:±1bpm or ±1 %
Measurement range: 0~150mmHg
ST segment analysis (Diagnostic mode):
Accuracy: ±2 MmHg (0~40)mmHg, ±5% (41~70)mmHg
a. ST range: -2.0mV~+2.0mV
±8% (71~100)mmHg, ±10% (101~150)mmHg
b. ST accuracy:±0.02mV
Response time: <3 seconds
Monitoring mode: Diagnostic 0.05 ~ 100Hz
Monitoring 0.5 ~ 40 Hz
IBP
Operating 1.0 ~ 25 Hz
2 Channels
Range: -40 ~330mmHg
◆Non-Invasive Blood Pressure
Accuracy: ±4 mm Hg or ±4 % (take the greater one)
Measurement type: adult, pediatric, neonatal
Measurement range:
Recorder
Adult: Systolic 40 ~ 270mmHg
Thermal array recorder
Diastolic 20 ~ 200mmHg
Mean 30 ~ 220mmHg
◆Environment
Pediatric: Systolic 40 ~ 180mmHg
Operation Storage
Diastolic 15 ~ 160mmHg
Temperature 5 ~ 40 ℃ -20 ~ 55 ℃
Mean 20 ~ 170mmHg
Humidity ≤ 90% ≤ 95%
Neonatal: Systolic 30 ~ 140mmHg
Diastolic 15 ~ 100mmHg
◆Power Requirements
Mean 20 ~ 115mmHg
Input: 100~240 VAC, 50/60Hz
Accuracy: Meets ANSI/AAMI Sp10 standards
Consumption: ≤ 80VA
Over pressure protection
Battery: +12VDC rechargeable battery
◆Pulse Oximeter
◆Compliance
SpO2 measurement range: 0 ~ 100 %
1. SpO2: ISO 9919
Pulse rate measurement range: 30 ~ 250 BPM
2. Safety Standards: EN 60601-1
Accuracy: ± 2 %
3. Alarm: IEC60601-1-8
4. EMC: EN 60601-1-2, Group 1 Class A
◆Temperature
5. Environment : WEEE (2002/96/EC)
2 Channels
Measurement range: 25 ~ 45 ℃
Accuracy:±0.2 ℃